Residential wiring takeoff
Receptacles, switches, GFCI and AFCI devices, smoke and CO alarms, circuits, breakers, NMD90 cable and boxes for a house, from its area and room counts.
Your job
Current editions require AFCI protection on most 125 V, 15 A and 20 A receptacle branch circuits in dwelling units. Provincial amendments vary; confirm the scope with the authority having jurisdiction.
Answer
- Circuits
- 16 branch circuits
- Receptacles
- 46 (8 GFCI, 3 20 A)
- Switches and dimmers
- 10 single-pole, 4 3-way, 2 dimmers
- Lighting outlets and pot lights
- 14 outlets, 12 pot lights
- AFCI breakers
- 4
- Smoke and CO alarms
- 4 smoke, 1 smoke and CO
- NMD90 cable
- 414 m 14/2, 120 m 12/2, 29 m 14/3
- Receptacles per general room
- 5
- Counts are estimates from room counts and area. Receptacle numbers use a simplified dwelling-unit spacing assumption; confirm the required spacing against the electrical code adopted in your jurisdiction. A drawing-based takeoff will differ.
- The range, dryer and water heater circuits are not included; add them from the dwelling load calculator results.
- Smoke alarms are counted per storey and in every bedroom; carbon monoxide alarms by sleeping area. The count assumes carbon monoxide alarms where a fuel-burning appliance is present, near the sleeping areas. Confirm the alarm requirements in the National Building Code and your provincial amendments.
Method: CEC dwelling-unit receptacle-spacing, GFCI and AFCI requirements vary by edition, location and provincial amendments; confirm the applicable requirements with the authority having jurisdiction; Confirm circuit-loading and outlet requirements against the electrical code adopted in your jurisdiction; NBC smoke-alarm and carbon-monoxide-alarm requirements are described in words only; Cable: 4.5 m per outlet plus a home run of 6 m, 4 m per extra storey and 0.3 x the square root of the area; 10% added for waste; Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.
Estimating aid based on a summary of the CEC. Provinces adopt different editions and amendments. Confirm with the authority having jurisdiction, and the engineer of record where one is involved.
Priced takeoff
- Receptacle 15 A tamper-resistant$105.3535 ea at $3.017 h
- Receptacle 20 A T-slot tamper-resistant$25.053 ea at $8.350.66 h
- GFCI receptacle 15 A$226.008 ea at $28.252 h
- Weatherproof in-use cover$34.342 ea at $17.170.3 h
- Switch, single pole$26.0010 ea at $2.602 h
- Switch, 3-way$56.364 ea at $14.091 h
- LED dimmer switch$121.162 ea at $60.580.6 h
- Cover plate$154.3862 ea at $2.491.86 h
- LED slim pot light 4 in$200.0412 ea at $16.674.8 h
- Breaker 15 A 1-pole$105.847 ea at $15.120.7 h
- Breaker 20 A 1-pole$74.505 ea at $14.900.5 h
- Breaker 15 A combination AFCI$365.924 ea at $91.480.6 h
- Smoke alarm, hardwired with battery backup$270.564 ea at $67.641.6 h
- Smoke and CO alarm, hardwired$110.091 ea at $110.090.4 h
- NMD90 copper cable 14/2$885.96414 m at $2.1410.35 h
- NMD90 copper cable 12/2$417.60120 m at $3.483.36 h
- NMD90 copper cable 14/3$80.0429 m at $2.760.87 h
- Plastic new-work box, single gang$179.8062 ea at $2.909.3 h
- Octagon box 4 in$51.9414 ea at $3.714.2 h
- Materials
- $3,490.93
- Labour, 52.1 h at $99.00
- $5,157.90
- Your cost, before markup and tax
- $8,648.83
Reference prices are dated baselines (2026-11) for Ontario. Confirm them with your supplier. In TradeQuote PRO your own saved prices replace these.
How it works
You enter 14 inputs. The calculator returns the quantities, rounds them up the way the material is sold, and lists the takeoff so it can be priced.
- Finished living area, all floors (m²).
- Storeys above grade.
- Bedrooms.
- Bathrooms.
- Other rooms (living, dining, family, office).
- Kitchen counter length along the walls (m).
- Laundry area.
- Attached garage.
- Exterior receptacles.
- Pot lights.
- Finished basement. Adds a smoke alarm on that level.
- Fuel-fired appliance or attached garage. Requires a carbon monoxide alarm.
- EV charger circuit.
- AFCI protection. Current editions require AFCI protection on most 125 V, 15 A and 20 A receptacle branch circuits in dwelling units. Provincial amendments vary; confirm the scope with the authority having jurisdiction.
The method
- CEC dwelling-unit receptacle-spacing, GFCI and AFCI requirements vary by edition, location and provincial amendments; confirm the applicable requirements with the authority having jurisdiction
- Confirm circuit-loading and outlet requirements against the electrical code adopted in your jurisdiction; NBC smoke-alarm and carbon-monoxide-alarm requirements are described in words only
- Cable: 4.5 m per outlet plus a home run of 6 m, 4 m per extra storey and 0.3 x the square root of the area; 10% added for waste
- Check against the CEC edition and amendments your province adopts; confirm with the authority having jurisdiction.
Check results against the code and manufacturer data that apply to your job. Prices are dated baselines to confirm with a supplier.
Add this to a real estimate in TradeQuote PRO
The takeoff lands as estimate lines with your prices, markup and tax, then becomes a proposal the client signs.
More electrical calculators
- Voltage drop calculatorVoltage drop in volts and per cent for copper or aluminum conductors, checked against the Canadian Electrical Code 3% and 5% limits, with the smallest size that passes.
- Conductor check (ampacity)Checks a conductor against a load: required ampacity with the continuous-load factor against the ampacity you read from your code book, corrected for ambient and conductor count, with pass or fail.
- Conduit fill calculatorConduit fill from the conductor and conduit diameters you enter, checked against the 53/31/40 per cent fill limits, with conduit, couplings, connectors and wire for the takeoff.
- Box fill calculatorAdds up the applicable box-fill allowances you enter for conductors, devices and clamps, and compares the total with the volume marked on the box.